Answer Posted / khalidshaikh
1.MEGGER WORKS ON THE PRINCIPLE OF OHM;S LAW.
2.FIRST OF ALL IT GENERATES HIGH VOLTAGE THROUGH ITS
GENERATOR OR DC/AC CONVERTOR AND VOLTAGE MULTIPLIER.
3. MORE THE VOLTAGE GENRATED BY GENERATOR MORE ACCURATE THE
RESULTS.
4.IT CALCULATE THE INSULATION RESISTANCE OF THE CIRCUIT
UNDER TEST BY SUPPLYING HIGH VOLTAGE ON THE ENDS.
5. WHEN THE CIRCUIT HAS HIGH INTERNAL RESISTANCE MORE
VOLTAGE DROP AND LESS CURRENT FLOWS AND VICE VERSA.
IT SUPPLIES THE VOLTAGE AT THE RATINGS OF 1 KV, 2 KV, 5 KV
10 KV , 20 KV AND SO ON.
MORE THE VOLTAGE RATING MEGGER WILL BE ABLE TO MEASURE
MILLIONS OF MEGA OHMS AND UP TO INFINITY LEVEL.
| Is This Answer Correct ? | 24 Yes | 3 No |
Post New Answer View All Answers
Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.
what is the internal working of star delta starter
which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant
i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?
hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly
WHAT CAUSED THRESHOLD VOLTAGE TO EXIST?
WHat is the general checks required for Dry type transformers
any one guide me to reduce the power factor of diesel Generator from 0.97 Leg to 0.8 Leg.with out any change in my load.
how does an centrifugal and screw type chiller will work. which chiller efficiency is high and why.
for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?
From past few months I am getting lagging pf even though sufficient capacitors used in circuit. Where is the problem pls answer
how to calculate the battery AH
What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?
How to decide and select the different earthing wire size for the different types of earthing
how to find motors H.P. whout any rating? (only give you a motor and multimeter)