Answer Posted / yuvi
The weak link will break first. we have 3 components
the source>>the conductor to connect to ground and earth.
Earth is the only component that has least probability of
burning out. the conductor or the source will burn out if
they are unable to handle the massive current. If they are
able to handle it, the high current just keeps flowing
through the circuit.
| Is This Answer Correct ? | 2 Yes | 3 No |
Post New Answer View All Answers
difference between power surge and switching transient
Refernce currents are to be generated using refernce cueernts how can this be done??
how does the terminal voltage of transmission lines increase when a capacitor is connected???? This happens not only in transmission lines but also in all circuits. How??? When a capacitor is connected in a transmission line, capacitor also takes energy from the same supply. But how is it able to increase the terminal voltage??? Practically What sequence of events happen during increase in voltage???
Why is the air gap between the pole pieces and the armature kept very small?
why do we carry out winding resistance test?
why is control bus bi-directional?
how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???
what is the differation bewreen kwh & fundamental kwh in electronic trivector meters
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?
What is the mechanism of WTI
CALCULATE THE TOTAL VOLTAGE DROP AND SELECT THE CABLE SIZE IN MM-SQARE FOR A PANEL-262KW AT 110 METER FROM THE SOURCE SUPPLY , SUPPLY VOLTAGE 240/415
please describe the Transformer setting, Motor setting, I/C setting, Tie setting
Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?
FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?