Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the differnce between ac and dc?

Answer Posted / ibrahim

frequency,
i ac frequency exist
in dc frequency does not exist
this is the major diff between ac &dc

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in indoor type circuit breakers why only the corner breaker trips specially during cold season. What is the reason.

1879


for a 400kv t/m line with 10 ampere current will corona occur?

2193


What is the effect of solar radiation on the design of an Isolated Phase Busduct?

2362


WHAT IS MOBILE SUB-STATION? & REALLY BENEFIT IN INDIA

2073


how to operate and maintenance of 1500 kva diesel generator set

1811


we have amp, voltage, kw, length detail then how to calculte copper & alluminium size of conductor of 3-phase induction motor

1462


as a electrical student why should i hire you?

2497


area control error

1731


i have a 1500kVA transformer what is the kWH meter i need to use?

1782


Can a generator runs after getting 1st stator earth fault.

1409


Difference between low impedance and high impedance Restricted Earth Fault

3120


i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.

1622


we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan

1679


What happens when two positively charged material is placed together?

1137


During underground cabling in landscape area what did we cover the cable with to prevent the electric shock & protect the cable?

1875