Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

HOW CIRCUIT BREAKER RATING CALCULATED?WHAT ARE THE
PARAMETERS CONSIDERED?

Answer Posted / r p payasi

kVA rating=Sqrt(3)*KV*Fault current(max)

so required is
1.Voltage of line
2.max fult current

Is This Answer Correct ?    14 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why PT voltages are measured with respect to ground? What do u mean by voltage or current polarized.

2358


The sodium vapor lamp is not glows when it is connected a distance of 5 meters above from gearbox, why ?

3657


difine electrical ballast in HPSVL

2062


In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?

1963


what is effect of leading power facter on the system and billing

2320


kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased

2638


What is the rotor frequency of 10 Hp 1440 RPM 50HZ 415V ?

1914


hr round

2110


what shall be no load voltage of 132/33 kV transformer ? is it 33 kv of 34.5 kV

2173


how circuit breaker work.. what is the operations taking place inside a circuit breaker when an overcurrent occurs... is it similar to fuse?

2058


i am completed in B.E(Electrical and Electronics Engineering) with 8 months experience in Quality Control Engineer at Bharathi Industries,Coimbatore.

1868


What is the effect on in Zone and out zone fault if Phase side CT is Vk/2<30 mA and Neutral side is CT is Vk/4<30 mA for Transformer REF protection

3803


why we use condenser in the thermal power plant, althrough the same vapour will be again heated

4845


how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me

1887


in ACB breaker requireding 3200Amps. buscoupler getting OFF mode and again it reset and getting normal position give me a required answer?

2322