why the power cut problems occur in tamil nadu?
may i know the exact reason.plz
Answer Posted / ramniveth
hello Mr.sennapparajan are you sure that our TNEB dont have
talented engineers . have you ever read the book issued by
TNEB engineers for "testing ,commissioning and maintanance
of electrical equpments" which is used all over the India.
coming to the question we require more power but we are not
generating as much power we consume .as the generation is
low they are making backups by powercut.
but the places for frequent powercut is not an electrical
related issue
| Is This Answer Correct ? | 71 Yes | 19 No |
Post New Answer View All Answers
which is the best institute for PLC,SCADA,DCS in hyderabad
what is difference between isolation and ultra isolation transformer?, what is the method of testing ?
Write a note on materials used as a fuse element.
do anyone out there know where to find a compleete list on acronyms/abbreviations used in offshore electric engineering. MCB - Micro Circuit Breaker, MCCB-Mouldes Case Circuit Breaker, ELCB-Earth Lekage Circuit Breaker, ELMCB- etc.....
HOW THE OLTC TRANSFORMER SAVE ENERGY IN COMPARISON TO OFF LINE TRANSFORMER AND IS IT ECONOMICAL TO REPLACE THE OFF LINE TRANSFORMER TO OLTC TRANSFORMER
Earth has zero potential then what would be the neutral potential ?
Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.
EXPLAIN USE OF ROCKING ARRANGEMENT IN ELECTRIC HEATING?
FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?
what is value of Jin transformer
In siemens PLC, why do we want to move the data ?
why is control bus bi-directional?
how withstand of hi-pot test outputs of transformer wire 2.5mm
draw vector diagram and +ve,zero sequence diagram of symmetrical three phase fault.
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.