in trains i have seen the terminal which is connected at
the top of the train is positive .where is negative ?
track? i dont think so
Answer Posted / chandru_williams
The track acts as negative path. the circuit closes in the
track.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
(In MEP services) HVAC in AC Plant room what else can we provide if the chiller is not considered?
why would amp draw on neutral wire be as much as amp draw on the hot leg.
What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
What is the permissible maximum flux density in transformer core?
In EDO ACBs what is a purpose of closing coil and motor, what is the operation of these devices are they inetconnected. means if we give supply to motor and by BCS we charge Closing coil,what exact is operation is and how it charge a spring of ACB. Sir if anybody has an wiring diagram please send me the link to operate and EDO breaker.
Why to keep capacitor bank off while generator running.
sir i have a car stereo system and there is jack on him so can u tell me a way to find out their power terminals on the jack or on the circuit board"
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
What is the diff. between single compression and double compression gland
What is the name of transformers oil filteration equipment?
How to Calculate the Fault Level of Electrical Installation
How is the connection of the tap changer on the HV side been made?
what is the size of cable for 15kw motor and 85 meter cable length using with vfd
Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?