WHY TRANSFORMERS ARE RATED IN 11KV 22KV 33KV Instead off
10kv 20kv 30kv
Answer Posted / chandru_williams
1. When an alternator generates voltage, its rms value is
given by 4.4*f*$*t, where $ is value of total flux per
pole. So we can see all the voltages are made inevitably
multiple of this value (1.1, which is the form factor of
ac wave). Also it provides us the best economic
construction of step up and step down transformers.
2. We always use a multiple of 1.11 bcoz for a pure sine
wave the FORM FACTOR is the ratio of rms value of voltage
or
current with the avg. value of voltage or current and for
pure sine wave rms value of current is Imax/root '2' and
avg. value is 2Imax/pie. and which comes out to be 1.11 so
we cant have a combination of other then a multiple of 1.11.
| Is This Answer Correct ? | 26 Yes | 4 No |
Post New Answer View All Answers
FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?
what are the things that can cause a three phase motor to crawl?
current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer
how we calculate the withstansing current capacity of wires&cables?
What are the conditions for sustained oscillator or what is backhouse criterion?
how to calculate current carring capacity of cable and cable selection? 1) copper flexible cable 2) copper armoured cable 3) Aluminium cable
Why you want to join non technical field when you are an engineer?
wow to calculate the transformer rating(KVA)
why would amp draw on neutral wire be as much as amp draw on the hot leg.
can u give me a brief idea about power line carrier communication ??
how much excitation voltage required to generate 1mw power?
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?
What are diffrent type of road taxes?
2. What are the parameters of EHT sub-station?