Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


1. What means HART communicator / where it is used /
how to use it?
2. Types of Thermocouples and its temperature ranges /
output of thermocouple?
3. Types of RTDs and its temperature ranges / output
of RTD?
4. Idea about Temperature Transmitters?
5. Difference between Analog and Digital signals?
6. Difference between “2 wire” and “4 wire” system /
instruments?
7. Difference between “Potential” and “Potential free”
contact?
8. Types of flow meters / transmitters?
9. Types of level transmitters?
10. Difference between “Power/Control” cable
and “Instrument” cable?
11. What means “shield” and “screen” in cables / how it
is useful?
12. Draw a schematic of closed loop circuit of flow /
level / pressure / temperature?
13. Idea about calibration of Control valve /
positioned / I/P?
14. How to bypass a digital/analog signal in PLC/DCS by
hardwire and software?



Answer Posted / rajesh

1.HART is Communication Protocal.it is used to Communicate
the Field Instruments for measuring and Calibrating purpose
2.K Type : 0-1370 degrees
J Type: 0-700 degress
B Type: 200 -1800 deggress
R type: 200 - 2450 degrees
Output of Thermocouple is DC Potential (milli volts)
3.Platimum RTD :PT-100 Range:-270 to 600 degress
Output of RTD is Resistance
4.Temparaure tranmitters
it will receive the sinal from sensor (thermocouple /
RTD) and this signal will convets to 4-20mA or 0-20mA
5.Analog Signal is contioues measuring signal ie it's
measuring Range is 0 to 100%
Digital signal is a Binary form ie. Its state is Either
High (1) or Low(0)
6.in 4 wire Tranmitter Have Seperate exitation Supply is
for its Operation and Output taken for seperately.if the
Tranmitter Elecronic Cercuit is drawing More than 4 ma of
current then it will apply the 4 wire scheme.
in 2 wire Tranmitter working supply and its output is
taken in same cable.ie its working supply is lessthan 4 ma.

Is This Answer Correct ?    63 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to regulate the flow of Air in 4" line, with max flow of 330 nm3/hr and Pressure of 0.5 bar? please suggest the type of instrument required.

1445


why I need valve guard and whats different between guard and positioner ??

1326


sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com

2287


how works encoder in plc

2014


How does your previous experience relate to the job you are applying for ?

1963


what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1927


how to rectify the poor signal strength in utrasonic digtial flow meter ,model:ge digital xce868i

1195


Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?

1822


WHAT IS MEANT BY PROJECT MANAGEMENT STRATEGIES IN INSTRUMENTATION?

3466


Why humidity limit is 30 to 55 % for raw material storage?

4210


What is profibus?

1062


What are the interlocks we have to check during the start up of LP/HP compressor?

1931


What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch

2144


䑰ҕ䔈ҕ䖠ҕ䘰ҕ䛀ҕ䝐ҕ䟐ҕ䢐ҕ䥐ҕŹ

1921


Who to difference between analog in & analog out in dcs?

1555