Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why the Proximitor supply should be Negative voltage? Why
should not we give Positive voltage to the Transducer?

Answer Posted / grajesh

Because Proximity will induces the Positive field

Is This Answer Correct ?    2 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to relay switch sense the fault?

2544


Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...

2293


Isometric drawings are generated during _________________ phase of a project

2017


what will the sending unit in the fuel gauge utilizes?

1844


Describe how to use megger to measure the earth resistance and insulation resistance

2165


hi! i want to know about mpse exam.

2228


KAlman filter code for two dimension?

2013


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1340


where proximity sensor installed on tank in loading arm application

1909


What is the start up procedure of desalter

3617


what is diffrance between FF & SMART, explain with difination

3136


how to calculate control valve bonnet size?? or how to select its material?

2375


what is Best Among SINK Or SOURCE Type Design In Digital Signal, Either Iput Or Output? WHY?Can any one..

2104


what can of fault ofently come in vibration mesurement?

2091


the output of the common trasmitter protocol in qatar gas are the following

1955