WHY TRANSFORMERS ARE RATED IN 11KV 22KV 33KV Instead off
10kv 20kv 30kv
Answer Posted / shankar rao
Transformer rating depending up on Emf induced on Trafo.
Emf. induced Eqs. is depending up on Farm factor : 1.11
| Is This Answer Correct ? | 25 Yes | 7 No |
Post New Answer View All Answers
defult setting in p220 micom motor proction relay for 11kv,640kw,f.l.a.-40a,1440rpm ht motor?
In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
1.what is difference in maintain Hz again Hz in USA ? 2.how to calculate the battery AH? 3.why are yearly maintained in transformer how many tests in required?
Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar
what r the safety measures in UPS ? explain all?
give me applications of sequence bridges . (used in 3 phase un balanced systems)
what does vector group Dyn11 tell us? also tell me how will u differentiate between phase lead and phase lag thru this vector group
Explain Active power,reactive power,how its related to each other , & inductive ,capacitive.
What is the vector group of a transformer,how can it be found out?
How impulse levels are calculated that for 11kV impulse is 75kvp, for 24kV impulse is 125kvp ?
HOW TO CHECK THE VECTOR GROUP OF A TRANSFORMER YD11?
Why synchronous motor is used in power factor improvement,dc series in lift
What happens to a line-frequency of high-frequency transformer when it is first energized/ re-energize?
What should be the percentage increase in length of the dead end clamp for bus bar conductor (Hawthorn) after hydraulic pressing and what should be the applied pressure?