Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHY TRANSFORMERS ARE RATED IN 11KV 22KV 33KV Instead off
10kv 20kv 30kv

Answer Posted / suneetha

this is due to form factor
rms value of induced emf= form factor * average value

form factor is calculated as 1.11
so the ratings are usually expressed in multiples of 11

Is This Answer Correct ?    72 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what id a dry type transformers and its function ?

1830


How is efficiency of DG set calculated? At many places I found the efficiency to be mentioned in percentage. But at some other places I found kWH/ litres. I want to know how dimensionless percentage value is arrived at?

1977


Why is water motor not taking the pressure? what is the problem?

1626


explain why core loss of a transformer is almost constant under different load conditions when connected across a constant voltage and constant frequency.

2760


we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.

7219


how to calculate compresor capacity?

2250


What are the different methodes for calculating the short circuit Current?

2113


Capacitor is load free component but why ampere meter shows current when capacitor bank breaker close?

1239


If any one's require of phoenix contact like( relay , termilnal block , surge protection device ) , product please contect me 09878206357 chetan verma

2166


State thevenin’s theorem?

1160


can we make a electric generator,which can not use any type of fuel,air,solar,gas,thermal,coal,petrol,etc and able to produce electrical energy (or self electricity generating generator)

1983


how test transfomer(3 phase75kva) by megger

2177


what is Anti-pumping?

1988


After synchronization with grid what is the demand value QKVAR and how we will maintain that?

2322


why HT armoured cable does not glanding

4316