How do you think they do earthing or grounding in ships and
aeroplanes?
Answer Posted / kumar
I think there v r using DC only..so no need of dc..
| Is This Answer Correct ? | 3 Yes | 29 No |
Post New Answer View All Answers
Why High voltage are generate noise ?
how to calculation increase power factor for single phase
What is the difference between the transmission line and distribution line?
Anybody know how schematic diagram for reverse power relay? RPR for generator protection
How to synchronization will be done between two DGs ?
what is metering cum synchronizing panel and how it is used?
Can anyone please provide me details of MCCB/Contactor/SFU rating calculations for a motor feeder..for example 50 kw.. not from type-2 cordination chart. i want manual calculations..
hi every body i am master student in control engineering and my project is slip control in trains i assumed a Dc motore as traction motor but i don't have characteristics of this kind of motor that is used in train. i want from every body if he or she has the characteristics or information about Dc motor that is used in train give me those information or technical characteristics .
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
what are factors to be consider in electrical installation like load factor,diversity factor .....
what is the purpose of silicon dropper used in battery charger?
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
what happend to DC shunt motor if its field winding insulation becomes slightly weak? will that motor can run on full load or not explain in detail. thanks
what is the terminal voltage of dc series generator running at rated speed at no load?
how to calculate the breaking capacity of different breakers.