Wht ar the reason for low voltage on consumer side?
Answer Posted / lavanya
during power transmission at the grid there is low voltage
and high currents and when it passes through different
substations it step downs and at that time there is high
voltage and when it comes to house hold purposes there is
low voltage in this ohms law does not work
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
What is MSL designation of a motor and same may be provided in details.
what is transformor oil gread
whether fibre optic cable in high voltage earth conductor is used for protection circuits
What is Instantaneous Earth fault relay,how will work
Why do not we prefer non conventional sources of energy to conventional sources?
What is tan delta & PPM in transformer? and whats its IS value?
Hi, Next week Iam appearing RRB exam for section engineer. So help me to get modal question papers for this position. Iam very thankful to you. Whether question will be fully techanical format or general form. Please give me a details regarding this exam.
i have gear oil pump with single phase motor.some time its motor starts running in reverse direction rather than forward direction...whats the reason behind this issue. 1- either capacitor is week? 2- or winding is week?
What is the instrument to check the rotating diode fuse of alternator in running conditions?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
how to find Harmonics and types as per the equipemnts
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
What is the working mechanism of OLTC in Power Transformers????
Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?
calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.