Answer Posted / aayush
But dear Sunil, how will I calculate that? If I have a 12V
Battery and I dont know its AH, then what is the method to
find that?
| Is This Answer Correct ? | 34 Yes | 12 No |
Post New Answer View All Answers
Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??
What are the advantages of using distance protection schemes as opposed to normal overcurrent/ earth fault protection on high voltage feeders.
WHY NUTRAL GROUND SYSTEM USED IN 33KV SYSTEM
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?
Mention the disadvantages of low power factor? How can it be improved?
In ACS 1000 drive we are using 12 pulse converter,why don't use 3 pulse converter.
How to know the Max. current caring capacity of the cable by its size ?
i applied for c licence with my one year apperents trainee and i have attaced with A grade contractor company experiance that is for 14 monts experiance this document is sufeicant for c licence? pls tell why they rejected
1.how many types of relays? 2.difference between ATS& STS?
high voltage transformer input voltage,current and amps rating..distributed transformer input voltage,current and amps rating...
What is the maximum and minimum rating of UPS?
hi frnds can any one help me ? plz send me placement paper of IOCL of Electrical streem .... plz send ....its urgent....
What are the protection required for Transformer, motor, Line, Generator, capacitor, that all i have to refer which standard?(Like Transformer detail IS 2026)
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.