what is difference b/w HT & LT and the range of HT & LT ?
Answer Posted / mike
Less say if you had transformer in a station it was a 100kv
to 44kv the breaker between the bus an high side of the
transformer protecting it from a fault would be the high
tension. Once it leaves the low side of the transformer it
goes to a breaker that is between the transformer and the
low side bus this would be your low tension. These breakers
have ct that protect the bank with differiential relays.
| Is This Answer Correct ? | 12 Yes | 30 No |
Post New Answer View All Answers
1.what is the difference between ct and cvt? 2.what is the difference between pt and cvt? 3.what is the difference between relays and circuit breakers?
which phase is preferred for connecting 1 phase vt used for synchronizing OHL? WHY?
Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you
thyristor controlled APFC panel design parameter?
from generating station If 400v LT line length is 1000m how much voltage is drop and how do i calculate it? which cable will be use for this line?
how unidirectional torque is produced in DC motor?
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
If symmetrical fault occurs at the terminal of a synchronous motor then how the motor will act...explain it..
Dg pf .71 i am improve pf 0.80 what capacitor connected in dg how?
1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)
What is called grain-oriented laminations?
why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?
What is Tachometer used to measure?
If 100 KAV USP dedicated earth got disconnect / Cut. What will happen at load.
How to calculate VA rating for CT or PT or Control Transformer?