explain the details about vaccum circut breaker and
advantages?
Answer Posted / j.kesavan
vaccum circuit breaker ,vaccum is arc qunching media, to
arrest the arc in breaker closing time.
| Is This Answer Correct ? | 12 Yes | 4 No |
Post New Answer View All Answers
george phenomenon of synchronous machine
What is the Surge for 1.1 Phase Induction Motor(For Eg.1Hp) 2.3 Phase Induction Motor(For Eg.1Hp) 3.AirConditioner(For Eg 1Ton) 4.Refrigerator(For Eg 180Ltr or 160kW) 5.Induction Cooker 4. Ceiling Fan
how to find out 3 phase complex power in per unit in unbalanced system?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
how many joint can done in HT line and what is life of the joint
How can we measure earthing resistance test (Earth meggar) of Transformer neutral pit while in live condition?.
1 “earthing” for bonding of equipment and circuits to common plant earth electrode potential, 2 “protective earthing (PE)” when this bonding is required for personal safety provisions 3 “grounding” for interference suppressing bonding of screens, sys-tems with ground level 4. low-impedance earthing ? 5.primary earthing system and secondary earthing system what is that? 6.earthing electrode or mesh net earthing electrode ? very confusing , simple but very informative help required ? i will be very very thankful to you guys.
How can two 3 phase transformers of same KVA and Voltage be connected in parallel?
how does WTI work ?
For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
How will change the frequency in distribution side?
how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment
Explain the difference between verilog task and verilog function?
Draw the single line diagram of the power station?