What is basic difference between Soft Starters And VFD
drives?
Answer Posted / raneesh
Soft starter starging the motor in diarectly. But VFD
giving freequncy in one by one ie howmuch speed requred for
that motor that only giving the VFD. thats why we can
controll the fan speed and power conseption olso.
| Is This Answer Correct ? | 21 Yes | 4 No |
Post New Answer View All Answers
IN induction motor pf is increased using capacitors.what will be the effect on motor and system when very large capacitor is accidently installed and pf goes leading.
i am completed diploma in ece,and working in ht and lt lines.so is elligible diploma in ece for get electrical C Licence?plse give ur opinion?
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
TYPE'S OF BREKAR ,WHAT IS TRANSFORMAR & SAFTY. STARTER DOL & STAR DELTA STARTER.
Direction of flow of active power and reactive power with logic?
How to know any size of cable if there are not written on cable? Answer must be theurical not by experience.
Why you are switching off arc protection mcb when you are taking shutdown for lv board.
what is vtg limit of earth and neutral at transformer side?
WHAT IS MEANT BY SHEATH VOLTAGE IN 132Kv cable?
Dear sir, By which formula u can calculate for a particular kv line there is a range of mw.
CPC cable .PVC \1C....I want to get sure that type is flexible indoor or to be install on trench. please advice .thanx :)
how to differentiate a mpcb,mcb with a contactor? Explain their working operation
What will happen if we on 200kvr capacitor bank(11kv in bus)If there is low load on transformer (1.5 mva 33/11 kv)
is all the servo motors having brake?please specify which servo motors having brake for stop on position and which are not.