MCB is used for high rating &MCB is used for lower
rating.What is technical difference between ACB & MCB?
Answer Posted / parveen yadav
ACB & MCB both are circuit breakers the only diffrence is
of number of operation, Size, operational machenisem,
cooling system, breaking capacity.due to all above factors
ACB used for high rating and MCB used for distribution
system.
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).
What is knee point voltage of transformer?
how we explain parallel paths armature winding?
Why can't we take NO LOAD TRIAL of motors having V1 mounting??
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
what is the earth current,reverse power,electrical trip generator short circuit,low voltage, high voltage please discribe me
What is the earth treantment procedure?
why transformer tank is in rectangular shape what happen when it is in step shape
why the NGR (neutral grounding resistor) always OFF during DG off?
What is meant by coupling capacitor?
what is the current setting for different relay protection for transformer .
Why does the radius of armature is less than the radius of pole shoe?
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
If i have two 3000 kW motors and the whole facility requires a 10 MVA transformer. What would be better installing two 5 MVA transformers(one for 1 motor ) or just a single 10 MVA transformer for both of them. Give reasons for your answer.
Why is a plain induction motor unsuitable for wide speed control?