why motor starting current is High ?
Answer Posted / electrical
V=Eb+IaRa,Eb=back emf
At starting there is no back Emf
And V (Normal Supply Voltage)=220V(single Phase)
Ia = Armature Current
Ra = Armature resistance(Usually less (.2 to .5 ohms)
From the Above equation,
Ia = (V-Eb)/Ra
Since Eb is Zero, the above eqn will become
Ia = V/Ra (220/0.5 = 440A)
So at starting the current thru the armature is very high
to minimise this we are using the starters.
| Is This Answer Correct ? | 24 Yes | 1 No |
Post New Answer View All Answers
What is the meaning of C1, C61, C91 cable
what is the difference between 50 hz freq. and 60 hz freq.? which is better and economic in them ?
What technology is used in latest generators?
why various test are performed on electrical panels & power cables before commissioning on site & what are these test???
We have 110Vac ,10A ac supply which is converted into 110VDC & How much DC current? which factor is reqired for dc current calulation?
can anybody send the rrb chennai &rrb bopal question papers of 2006&2007.My exam is on 12 oct 2008.Its urgent
dc supply given to dc generator winding.how is possible? my knowledge is saying the winding will burn. please reply.
Explain the following and how these are working with PLC Unit 1 I/O Module Card 2 Adaptor Card 3 Ribbon Adaptor 4 I/O bus 5 I/O Devices
What is the formula formula for Busbar sizing and what are the things to be consider for Busbar Calculation?
what is inverter and converter
What must be the minimum distance maintained between 2 Generators as per International standards?
How is the percentage impedence of a transformer fixed at design stage???
Define conversion efficiency of a power amplifier.
sir please send me previous year questions of jspl of electrical section through which i could prepare myself fpr the test.
Define the overload capacity of the motor?