Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In case of a beam ,main steel is provided along the longer
span because, bending moment is directly proportional to
length but why in case of one way slab main steel is
provided along shorter span while as bending takes place
along longer span?comment

Answer Posted / ramiz,guwahati

BECAUSE IN CASE OF ONE WAY SLAB THE LOAD IS TRANSFERED
THROUGH THE SHORTER SPAN ONLY.

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the steps involved in the concreting process?

1301


States some of the tool bars used in cad?

1117


sir I got selected in rail vikas nigam limited and they call for interview but i don't what they will ask in interview please guide me if you have any experience

2423


Design a built-up column carrying an axial load of 1200 KN. Its length is 8m and it is effectively held in position at both ends and restrained against rotation at one end. Assume yield stress of 250 mpa

2161


can i make bricks using M10 grade concrete ? and what would be the cost of a brick if we use m10 grade concrete sand and aggregates ??

2214


how much deduction will be in 32 mm dia HYSD steel bar for 45 and 90 degree bend

1985


In a concrete grade C35A, C & A stands for what and equalent cube strength?

3598


What are the strongest shapes in building?

1081


find the discharge of water through a horizental venturimeter having 400mm dia at the inlet main and 150mm dia at thorat.if the diffrential gauge between inlet and thorat shows a pressure head of 25cm mercury. assume coefficient discharge 0.98 and specfic gravity of mercury as 13.6.

2193


What is 1/8 on the architect ruler denotes?

1087


can you provide a link for manual design of building?

1509


how to do sudoko puzaals?

2218


how can we calculate steel value, depending on load

2240


Define What happens to Load at yielding ?

1754


what is Brick crushing strength(PSI)?

1235