Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how make to Incident and accident report

Answer Posted / badshah

Accident/Incident Report should have a Preliminary &
followup Report. Preliminary Report contains details like
Name of the victim, equipment or an property damage & their
details and Place of Happening, date & time of incident.
Immediate Supervisor or in charge name contact no., Brief
description of the incident happened, Name of any witness.
Check Whether Safety precautions done as per Legal, Company
policy, procedures are followed are not and identify the
causes if required. Check whther Risk Assessment is done
for that activity. All the above points should be
considered in making the report.

Followup report should contain the description of the
accident to be filled by the in charge or supervisor after
investigating the incident and to be reported within say 3
days.. This also caontains the Senior or Managers comments
to avoid the incident.
Followup report will be replied by HSE or higher authority
with recommendations to avoid such incidents...so a
corrective action sheet is also included along with
followup report which will have recommendations from HSe or
higher authority and Action taken for the recommendation
which has to be replied by Manager of the concern or victim.

All officials involved like supervisor, manager, HSE
personnel should sign at respective places in the report.

A time frame to be set for replying for the recommendations
by HSE.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw transformer phasor diagram.(full load,no load)

4191


Draw the DOL starter and star delta starter drawing?

3007


hi can anyone pls tell me the eee interview core questions asked in l&t

2070


What is the unit of attenuation?

1088


What is Diff btw Fire Alarm & VESDA System???

2413


What are the necessary components of the feedback control system?

1237


Can anyone explain me about the capacitor calculation

2207


what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.

18455


WHAT WOULD BE THE FORMULA OF WIRE GAUGE FOR A FULL LOAD CURRENT

2335


hey guys help me out.....what  are the industrial uses/functions of nozzles in industries 

1600


USE OF 8 WAY PAN ASSEMBLY

1971


do anyone out there know where to find a compleete list on acronyms/abbreviations used in offshore electric engineering. MCB - Micro Circuit Breaker, MCCB-Mouldes Case Circuit Breaker, ELCB-Earth Lekage Circuit Breaker, ELMCB- etc.....

2093


What is vaccum currcuit breaker.define with cause and where be use it device?

1127


What is the capacity of the Fastners 12mm?

2456


What is the limitation of kirchoffs law?

1142