Answer Posted / badshah
Accident/Incident Report should have a Preliminary &
followup Report. Preliminary Report contains details like
Name of the victim, equipment or an property damage & their
details and Place of Happening, date & time of incident.
Immediate Supervisor or in charge name contact no., Brief
description of the incident happened, Name of any witness.
Check Whether Safety precautions done as per Legal, Company
policy, procedures are followed are not and identify the
causes if required. Check whther Risk Assessment is done
for that activity. All the above points should be
considered in making the report.
Followup report should contain the description of the
accident to be filled by the in charge or supervisor after
investigating the incident and to be reported within say 3
days.. This also caontains the Senior or Managers comments
to avoid the incident.
Followup report will be replied by HSE or higher authority
with recommendations to avoid such incidents...so a
corrective action sheet is also included along with
followup report which will have recommendations from HSe or
higher authority and Action taken for the recommendation
which has to be replied by Manager of the concern or victim.
All officials involved like supervisor, manager, HSE
personnel should sign at respective places in the report.
A time frame to be set for replying for the recommendations
by HSE.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
Draw transformer phasor diagram.(full load,no load)
Draw the DOL starter and star delta starter drawing?
hi can anyone pls tell me the eee interview core questions asked in l&t
What is the unit of attenuation?
What is Diff btw Fire Alarm & VESDA System???
What are the necessary components of the feedback control system?
Can anyone explain me about the capacitor calculation
what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.
WHAT WOULD BE THE FORMULA OF WIRE GAUGE FOR A FULL LOAD CURRENT
hey guys help me out.....what are the industrial uses/functions of nozzles in industries
USE OF 8 WAY PAN ASSEMBLY
do anyone out there know where to find a compleete list on acronyms/abbreviations used in offshore electric engineering. MCB - Micro Circuit Breaker, MCCB-Mouldes Case Circuit Breaker, ELCB-Earth Lekage Circuit Breaker, ELMCB- etc.....
What is vaccum currcuit breaker.define with cause and where be use it device?
What is the capacity of the Fastners 12mm?
What is the limitation of kirchoffs law?