Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

whate is aelectrical power fector for exampal

Answer Posted / muhammad zubair

electrical power factor is the ratio b/w actual power(kw)
and apperent power (kva).and also ratio b/w resistence and
impedence of a circuit.when ohmic resistance and impedence
will come equal power factor will becom unity.we can
improve pf to control the inductive reactance of a coil.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Name a govt approved university which have 100% online engineering course.

1702


why are distributed windings generally used in alternators?

2713


WHAT ARE THE DISADTAGES OF SINGLE-WIRE-EARTH-RETURN SYSTEM USED FOR RURAL ELECTRIFICATION?

1965


DG SET BLOCK DIGRAM

2274


details of oil cell size of Breakdown voltage test of tranformer oil details as per Standardswith mushroom electrodes?

1867


How each of the following losses occur in d.c machines (i) copper (2)core (3) windage (4)friction please help me

2026


What are the basic elements used for modeling mechanical rotational system?

1089


Phase control and integral control are used for?

2306


why we are using Load factor?

1925


HOW can i REuse the fused MLL LAMPS & GLS LAMPS at our factory

1877


If a high resistance fault occurs,then what are the changes will happen in the system?

1439


at meter room 50 hrc switch installed,but there are not get earthing proper,so what happen?and 11kv transformer out put going in to hrc main 400a three nog each? so earthing is require for all switch? (some customer made earthing at there home.)

1893


why impedance relay is used for medium transmission line protection

2305


what is parellel power factor correction?

4367


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1841