Is it possible to get earth resistance value"zero" Ohm
practically???
If yes,which type of earthing???
Answer Posted / anand prasad yadav
depending on soil & best salution quiring in side the earth
pit.
| Is This Answer Correct ? | 2 Yes | 9 No |
Post New Answer View All Answers
what is motor capacity of 80TR chiller? and also say what is the formula related temperature, motor capacity, TR?
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?
Dear all, I'm manikandan I have done by DIPLOMA EEE from 2011 , I have 5 years of experience from Power plant instrumentation field , which one field is give long life & which one field is best ,I confused a lot and also I'm studying AMIE, can I choose which department from Section B examination? pls tell me
How we can change the direction of rotation of Induction motor? Prove it using graphical
What will be result if we connect LT votage to the terminal of HT motor?
What Is Sampling?
All tape of electrical questions Answers tape of motor transformer e.o.t crane
CAN U PLEASE TELL ME SOME G.D TOPICS FOR APGENCO INTERVIEW&G.D
What are the different losses In a de mac1une'! t.xplam
how does the thyistor work in dc drive?
when ac current flows thru d coil of a contactr,it energizes,magnetic field attracts d contact of the coil...nw wont dt ac current in d contct induce current back on to d coil thru mutual inductance leading to high currnt in d coil
11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
Why the unit sizes of hydro generating machines are not standardized as in case of thermal powerplants?