what is the principal of flow transmeter,level trans
meter,presser transmeter?
Answer Posted / d k sathish kumar
PRINCIPLE :
IT WORKS ON THE PRINCIPLE OF TRANSMITTERS.
TRANSMITTERS ARE DEVICES THAT RECEIVES INPUTS (PROCESS
PHENOMENA) SUCH AS DIFFERENTIAL PRESSURE, PRESSURE,
TEMPERATURE, ETC.. AND CONVERTS THAT IN TO A REQUIRED OUTPUT
(MAY BE 4-20 MA, MV, ETC..) WHICH IS THEN RECEIVED BY A
CONTROLLER OR INDICATOR.
FOR FLOW & LEVEL - DIFF. PRESSURE IS USED
| Is This Answer Correct ? | 14 Yes | 14 No |
Post New Answer View All Answers
why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V
Can any one tell me what type of question asked for instrumentation and control interview panel??? pls mail ramashankar.goel@gmail.com
WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN
Which is your favourite subject & explain any one topic of it.
How we calculate orifice plat size???
What is hp & mp seperator .& what is its working principle ?
Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
2. What is ultrasonic flowmeter?
please tell me what is a light up procedure of Cfbc boiler and what it's axuillaries of cfbc boiler?
what will the sending unit in the fuel gauge utilizes?
Give 2 application of quartz crystal used for process parameter measurement.
all types of liquid analyzer principle with drawing?
How earthing can be checked????
What is hp & mp seperator .& what is its working principle ?