What is meant by H.R.C fuse?
Answer Posted / jaykaran gadhvi
it is stands for high rupturing capacity fuse.
it has a advantage of current limiting featur...so its used
for protection of contactors which may melt for higher
value of current...you can see the autometic starter of
motor has contactors.used for swiching..so fuse is
connected in series with it..after 2 to 3 operation..there
will no us of fuse...as it melts due to overheating...for
30 ka short circuit current..it limits to 10 ka
current.s.c..which is the rating of contactors
Is This Answer Correct ? | 26 Yes | 6 No |
Post New Answer View All Answers
WHAT ARE THE DATAS REQUIRED FOR PROTECTION AND METERING AND CONTROL AND LOGIC PREPARATION,HOW TO STUDY THE PROTECTION AND METERING?
Why there are some equipment(i.e:TV) that using 2-pin plug instead of three? What happen if there is current leakage? Are we going to get electric shock??
why we use 630mm single core cable for transformer secondary side and why two neutral cable
What is the universal motor?
sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah
RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?
how to caculate cable size for diff types of loads? if anyone know the calculating procedure please tell me
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
sir, Is their any measuring unit of knoking? please explian?
hi....I am from india..i have completed my engineering in electrical and electronics field with 58.4% and my IELTS score is 5.5 bands....Recently i received my I-20 in computer and information science from Troy university in Alabama.On 18th i have a visa interview can u please tell me what type of questions i have to answer ??????
What is lifting power for 1 wb/m2 and 1 A magnet?
given data are load current & power factor cable core size? plz any one update the calculation formula
how braking & making capacity of circuit breaker are calculated?
what is the vvvf in the dumbwaiter?? or lift. what is the actual process?/
How can we calculate strength of copper hich is supplying electric power to heater and in it hold the heater also and what r all types of forces which is acting on it...