1.Defination of Graund earth and neutral
2.

Answer Posted / rk

if current carying part of eqp i.e. trf or gen neutral is
connected to earth the it is generally called as grounding
on the other side non current carrying parts i.e. trf body
metal str of a S/S are usually connected earth knownn to
be earthing.

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate the External Resistance required for 60HP slipring motor in case no any data of the Motor is available???

1598


A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.

2445


11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?

1203


any one please tell taht what type questions will be asked in BHEL interview, i am having interview on 24th Dec, please send this to mail pradeepsistam@yahoo.co.in

1493


while doing high potential for 11KV 3 core cable how much leakage current will obtain?, what will be acceptance value?

2419






what is the size of cable for 15kw motor and 85 meter cable length using with vfd

1952


write a c++ code that receives an integer number and display the sum of the number and its revers integer?

1562


how to calculate units consumption for a 12 hp motor /hr.

1027


what is the formula to calculate voltage drop/loss on 66KV Transmission Line?

3211


why and how current drawn by battery charger depends upon the altitude where it is located?

1559


i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.

1456


We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?

1619


I want formula to calculate cable size as per load given in length & amp. I searched many sites but didn't right answer. Please reply me asap.

1033


why normally Generator rating are between 11Kv to 22Kv?

3704


What is the previous name of Cox's Bazar

1692