why dead weight tester called dead weight tester.

Answer Posted / kaushik

Dead weight tester is called dead weight tester because it
is working on dead weight principle that means there is no
variable parts in dead weight tester , Calibration and
Measurment done only based on simple dead weight principle
Weight = Pressure /Area

Is This Answer Correct ?    28 Yes 13 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Reason for capillary type dp level transmitter fluctuation

1521


can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).

1607


what is the vital subject for scoring bhel exam&what is the question pattern

1888


What is Positive Calibration and Negative Calibration?

1777


Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....

1658






how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744

1929


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1457


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

10408


how do calibrate the valves.. with clear manual

1561


If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1040


which type inter lock use in petrochemical refinery,and oil & gas?

2637


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

1930


what is gas metering system? gas chromatograph? and gas compressors?

1974


How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.

1638


Explain the burnout feature.

605