canu tell me why 4-20 ma and why not this 3-25ma?please
give reason of this value.
Answer Posted / vijay
usually there exsist linear relationship between this range
when you plot pressuer verses current graph. so depending
on application we can select o/p as 4-20mA or 3-15 psig.
also
for long distance transmission 4-20mA is good
| Is This Answer Correct ? | 11 Yes | 2 No |
Post New Answer View All Answers
Reason for capillary type dp level transmitter fluctuation
Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell
what is span value and zero ? and how set ?
Hi Friends , i need one urgent help , i am preparing for M.tech entrance examination , i need some obejective questions related to instrumentation field. where can i get those ? can anyone help me pls ?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
How to Calibrate Temperature Switch in field
why orfice is not used for main steam flow calculation
Speedtronic system .
Isometric drawings are generated during _________________ phase of a project
Why rdt and thermocouple both give different output .and one things more, how to generate ohm or mili volt plz mail me merajalam143545@yahoo.com
pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)
Explain the burnout feature.
Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.
How d.p. Transmitter can be applied to close tank?
What is the reason PT speed not incresed in gas turbine?