what is boucholz relay and the significance of it in to the
transformer?
Answer Posted / deepak vats
Boucholz relay is a device which is used for the protection
of transformer from its internal faults, it is a gas based
relay.
whenever any internal fault occurs in a transformer, the
boucholz relay at once gives a horn for some time, if the
transformer is isolated from the circuit then it stop its
sound itself other wise it trips the circuit by its own
tripping mechanism
| Is This Answer Correct ? | 11 Yes | 2 No |
Post New Answer View All Answers
What is kirchoff ’s current law (kcl)?
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
comparision between ACB and VCB
RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?
PLZ EXPLAIN THE INTERLOCKING AND CONTROLLING OF CONTACTORS????HOW CAN I DO THAT?
As a electrical engineer.. what are the basic norms should follow in transformer oil testing.. 1.What is the Electrode type? 2.How long time you will give for oil testing?
where the lexical paramater will use in fron end?
Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?
WHAT IS MEANT BY DERATING OF THYRISTOR?
At the starting of dc motor and syn.motor and induction motor high current flowing through the winding. Due to this the windings burnt out. To avoid this different types of starters are used. But incase of transformer what Will be used (At starting no emf is induced in the primary winding)?
If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..
why the active power flow of some line is increased when the active power of out is cut ?
If we impress a dc voltage of 230 V on an unloaded 230 V, 50 Hz transformer it wi A give high secondary voltage B burn out C give secondary voltage as per K D none of these
How to calculate loses in transformer of 160 KVA ?
What is the meaning of C1, C61, C91 cable