Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Power generation in India is at 50Hz while in America
its 60Hz so is there any advantage/Disadvantage of this ??

Answer Posted / vineeth

In my point of view,it may be due to the construction and
speed of the generator.We know that "f=NP/120".According to
this equation frequency is directly propotional to the
product of speed and the number of poles.For example,
speed,N=1500rpm and number of poles,P=4,then the
frequency,f=50Hz.If the speed,N=1800rpm,then the
frequency,f=60Hz.

Is This Answer Correct ?    13 Yes 31 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what may the reason for vector shift in a generator?

1827


What is the settings of distance protection relay in 400 kv line

1613


1.how many earth pits are required for 1000 k.w plant include substion , transformer ? 2. how many earth pits are required for 500kva generator.what is formula to calcute?

2846


what is x'mer ,isolation x'mer & yltra-isolation x'mer?????

2385


what is a pilot wiring and whys that called a pilot wiers

1857


Whether 3 phase induction motorwith 100 hp capacity , Amp 160 for which sensitive earth fault relay , type CTUM 15 can be used?

1420


how r charge carriers produced

2033


How earthing of switchgear system to be done.

1889


1. What is the exact formula for one weber? for example,(one ampere = one coulomb electron of electrons crossing a point of conductor at one second. i.e, 1A=1Q/1sec)

1842


Explain how you intend to work under pressure to meet up with deadline target?

2339


Testing procedure of DG alternator stability test

1481


What is Meter MF if External CT Ratio is 150/1 , PT Ratio is 132/110 Meter CT Ratio is 200/1 & Meter PT Ratio is 110/1

1807


What is different bewteen low or high impedance busbar protection scheme

4071


Why colled 440V to 3-phase supply.

2064


What is the lower limit of break-down voltage of converter transformer.

1858