Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is ment by KVAR and what are the advantage&dis-
advantages of KVAR

Answer Posted / mohd. karim

KVAR - Reactive Power
It's Present only in Inductive load, i.e. X-mer, Motor, X-
mission Line..etc

And This power is required for generating Magnetic field in
inductive load.

Here, i want to explain some formuls

KVA = Sqrt((kw)^2 + (Kvar)^2)
Where , KVA = Apparant Power
KW= Actual Power
Kvar= Reactive Power

PF=KW/Kva = KW/(KW+Kvar) = COS$

1. If the value of kvar is more. it means PF is Less.
2. If the value of Kvar is zero. It means Unity PF (PF=1).
it means Apparant Power is Maxi. and over KW Loading is
Maxi.

--> Practically PF is not Unity (PF=1). its near about One.

For Reducing Kvar Demand We install Capacitor In Ckt.

Dis-Advantage (If Kvar is More)

1. less KW Loading(Low load Allow) in system.
2.Power Factor will Poor.
3.High current in system so Conductor & Cable size increase.
4.Electricity bill will more (Money Loss)

Is This Answer Correct ?    33 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Name the types of motors used in vacuum cleaners, phonographic appliances, vending machines,refrigerators, rolling mills, lathes, power factor improvement and cranes.

1130


how can calculate 1kva generator running time in 1 liter keroscene

2597


why we use the 100% and 95% stator earth fault protection for the synchronus generator ?

2296


For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?

1956


what is the size of cable for 15kw motor and 85 meter cable length using with vfd

2345


why co incidence factor considered in transformer sizing?

1839


how to convert lv line to hv line and viseversa, any losses will occur during this process

2058


How can we calculate strength of copper hich is supplying electric power to heater and in it hold the heater also and what r all types of forces which is acting on it...

1963


Why the cores of large transformers build up of circular cross section?

2279


why servomotor motor? where i apply for best output?

2024


What is size 00, 01, 1 etc., in HRC fuse types?

2357


what is the acceptable limit value for Desolve Gas Analysis/

1963


we have 15 ampere variyac but we want 30 ampere variyac what we do

1912


What is an ideal transformer?

1142


what are the different methods for the starting of a synchronous motor.

1121