Why Current Transformers cannot be connected in parallel

Answer Posted / guest


CURRENT TRANSFORMER NOT CONNECTED IN PARALLEL DUE TO CURRINT
SAME IN SERIES AND DIFFERENT IN PARALLEL ALSO WINDING HAS
BURNED DUE TO SHORT CKT

Is This Answer Correct ?    10 Yes 18 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.

1467


Why we use 4-20 mA Analog signal for the PLC input? Why not 0-20 mA? Why not 5-25 mA?

2473


Explain using drawings what is reverse PID action w.r.t PID controllers.

2747


can we use CBCT in neutral of solidly grounded transformer? in place of three phases we can pass only one phase which decreases the size of CBCT?

1762


what is the difference between droop mode and ischnorous mode in thermal powerplant?

2164






Why do we pefer VCB over OCB?What are the advantages of VCB over OCB?

2076


PLS MENTION QUESTIONS ASKED IN IOCL INTERVIEW FOR ELECTRICAL EGG??

1953


Why r u using pf panel. what the uses

1505


how to convert lv line to hv line and viseversa, any losses will occur during this process

1597


whatare the disadvantages occur,if the form factor of transmission will not be equal to 1.11

1435


If we have 11 kv RYB Phase single core cable near about. Then wht effect and losses

1338


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1574


Why computer humming sound occurred in ht transmission line?

655


Whats the difference btwn a latch, port,data bus buffer? Do they all not hold data in d flip flops??

1951


howmany electrician should maintain for a 1000 kva used plant... in kerala..

1621