Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

HOW TO CHECK THERMOCOUPLE AND RTD & WHAT IS THE DIFFERENCE
BETWEEN THERMOCOUPLE AND RTD

Answer Posted / sushma

RTD will be find by R2=R1(1+alpha(t2-t1)) Thermo is used to
measure both AC&DC. In Teromcouple characteristics between
Rstistance & tepmerature is non-linear where as in RTD it
is linear.

Is This Answer Correct ?    25 Yes 46 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

2192


The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?

2258


how do calibrate the valves.. with clear manual

2070


why we use cascade control and feed foreword control in 3 element control of boiler drum ?what is feed forward and cascade control system ?

2205


What is the advantage of using locally fabricated hook ups over Pre fabricated hook ups in process instrumentation?

2022


Whatis the reset ofset and control system in instrumentation

2034


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

10825


WHAT IS THE DIFF. BETWEEN SKIN TEMPERATURE AND PASSES TEMPERATURE..?

2515


Any body have know try work calculation ???

1414


I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1781


Calibration procedure for electro magnetic flow meter

1970


TECHNICAL/ARTITUDE

2221


How servomotor controls throttle valve of TURBINE?

1933


components of control circuit belongs to control valve

1641


what is moisture probe? What are there types? What is there working principle and how they works? guys this is one of technical question I had ask in interview. If you know its answer please let me know. The interviewers were more interested in microwave moisture probe, so if you find its any link please just forward me on my mail id.avinash1200@gmail.com Thanks in advance.

2030