Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why earth hole size is biggest in plug point?

Answer Posted / mahadeva

The resistance of the Conductor is depending upon the area
of cross section of conductor i.e(R=6L/A), so we are
connected earth wire to the big one terminal of the socket
point as well as 3 pin top. To flow the fault current
through the terminal to earth easily.

Is This Answer Correct ?    22 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much costly in percentage wise is sandwich busduct costly than air insulated busduct of any rating?

1769


Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?

1415


What was the Dg set radiator and lube oil temperatures trip in ACB

1806


If more than rated DC voltage appears across trip coil of the breaker, what will happen? e.g. in 110V DC circuit system, if voltage across battery terminal showing 121 V

1640


Give some differences between open loop and closed loop?

1094


what is rocking arrangement in arc heating

2123


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1767


I'm looking for a mnaual set for a Teradyne J750. Softcopy would be preferred but I'll take what I can get.

2188


What is the resonant peak?

1165


What is mean by hot and cold loop testing? What is the difference between them?

1100


What are dependent sources?

1158


What is the formula to find out two phase active & reactive power

2174


draw the full wave and half wave circuit of 3 phase system and inverter circuit used in upsĀ 

2382


If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.

1602


In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.

1735