what are the differences between MCB and MCCB ?
Answer Posted / p. naik
MCB is acircuit-breaker which can provide protection only
in the cases of shor-circuit.They can only be operated
manually. MCCB's have provisions for both under/over
voltages, it has provisions for motr mechonism to be fitted
on it, which allows us to operate them electrically. MCCB's
have chnge over(NO & NC)contacts for both SD(faults) and SDE
(electrical faults) which can be utillised for providing
fault indication lamps. MCCB's have higher ratings than
MCB's. MCB's of diffrent types are B-curve(lighting
loads),C-curve(motors),D-curve(capacitive).Both operate in
almost a simillar manner having a fixed & moving contact,
but MCCB's been with more "ACCESSORIES".
| Is This Answer Correct ? | 8 Yes | 25 No |
Post New Answer View All Answers
1.What is the range of stator resistance of 3-phase induction motor? 2.Two electrically operated vibro motors are foxed in parallel direction in vibrating feeders. what is the direction of both vibro motors?
1. what is usage for power factor in industries?? 2.why we need to monitor power factor??
What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?
How can we find the breaking capacity of a Load breaker switch (LBS) fed from 11 kv supply??ex:50KA, 26kA etc???detailed step vice answer pls.
PLZ EXPLIN ABOUT CLASS PS CLASS CT .WHY THEY R DESINED AND FOR WHAT PURPOSE?WHY OTHER CT CANT BE USED AS PS CLASS CT? EXPLAIN IN SIMPLE LAUNGAGE IF POSSIBLE PLZ GIVE CIRCIT DIAGRAM?EMAIL-RAJ_SINGH_0376@SIFY.COM
difine electrical ballast in HPSVL
what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.
If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
What is the instrument to check the rotating diode fuse of alternator in running conditions?
what is the difference between general inverter and solor inverter clerly explain plz
What are the criteria shall be considers for sizing Fuse and MCB? If the rated current is 10Amps what should be the fuse size / MCB Size?
pls tell what are doing the three phase motor star and delta connetion with circuit diagram and control wiring .
H.t motor 6600 volt to same motor lt supply 440volt supply applyed to h.t motor to effect....
What is electrical cable termination