Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is short circuit force ? How to calculate it for Panel?

Answer Posted / lokesh kumar abb

i . L cross B
The B is represented in the form of I
So the formula comes out for per unit length as(N/m) for
single phase
2 x i x i /s x 10 e -4

where i is current and s is phase spacing in mm

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

lamination figures

1810


I have a reading off 1.5ohms at my mem my main c/b is rated at 40/6 amps in a domestic house and i was told to change it to a b curve c/b is this ok

1627


If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)

1937


What do you mean by per capita requirement of electrical energy in india

2195


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2102


Is electro plating what type of load whether resistive, inductive or capacitive loads

3271


why sometime we get electrical shock while touching the ballon of dish tv connection ? which we should not get.

1956


please send the IS strandard for electrical to sakthi_murugan86@yahoo.co.in

2216


What are the special cables required for explosion proof wiring?

16602


Explain the working principle of Synchronous Generator and Assynchronous generator?

2166


Give me the calculation steps to design an electromagnet to be work in 230V 50 Hz AC Supply. Also give force that is created by that electromagnet when it gets energized.

2179


What is the breaking capacity of transformer and how can we calculate the breaking capacity of tranformer

1844


what is EIB lighting control system? what is the advantages of this system?

3817


what is induction furnance? how many phase supply given io its coil for 15 or 20 ton furnance?

3338


why do we use spark detector inside the slip ring brush compartment 0ona slip ring induction motor?