Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is a circuit breaker. Weite the types of circuit
breaker.

Answer Posted / v.balakrishnan,shj

Circuit breaker is used to break the power supply from
loads like switch, but it also protects loads from over
current, short circuit and earth fault.
Types of Circuit breakers as follows:-
MV
1.Air Circuit Breaker (ACB)
2.Vaccum Circuit Breaker (VCB)
3.Oil Circuit Breaker
4.SF6 Circuit Breaker
LV
1.Air Circuit Breaker (ACB)
2.Moulded Case Circuit Breaker (MCCB)
3.Earth Leakage Circuit Breaker (ELCB)
4.Miniature Circuit Breaker (MCB)
5.Motor Protection Circuit Breaker (MPCB)

(by,V.Balakrishnan,Shj,050-8847343)

Is This Answer Correct ?    32 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?

2048


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2387


Q.1:What protection will be used on HT and LT side of 33/0.4 KV, MVA transformer. Indicate capacities of protective device to be used. Q.2:Which types of back-up protections are used in the power transformers? What do you understand by the term over travel in the relay? Q.3:How star and delta connected winding transformer are provided from earth fault

2128


I HAVE A 50A MCCB AS PER DESIGN LINE WIRE CONNECT UPWORD SIDE AND LOAD IS CONNECTED TO DOWNWARD SIDE TO THE MCCB.IF NOW ANY ONE CHANGE SUPPLY & LOAD(WISEVERSA) WHAT HAPPENS ? DOES MCCB OPERATION OR WORKING FUNCTION NORMAL IF YES THAN WHY THERE ARE MARKED LINE & LOAD ON MCCB.

2385


i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com

2017


Define peak overshoot.

1275


What is reactance, reluctance,capistance, pls give answeer in hinglish and be simply Jo asani we smajh m aa jaye

2118


how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets

2192


What is the formulae of Megger value for a A.C.Motor

2898


Hello to all, Please someone can send me HPCL ELECTRICAL Engg. Sample papers to me? Its urjent....my email address is.... raviasiapacific@gmail.com

2146


condition Autotrip facia come on control panel of electrical transmission line?

1578


What is meant by positive and negative feedback?

1052


plz send me the syllabus or any sample paper for engineer trainee recruitment if any,on ravinder911@yahoo.com

2168


Keywords: Die, Card, Coin, B/N 2 To 12

1284


what is the main function of capacitors in mccs.

1743