Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how induction generator works?

Answer Posted / ramesh pachamal

An induction generator is nothing but induction motor. if
the motor run more than the sysnchronous speed ie means the
slip goes on positive side it will feed the supply to same
feeder. but the excitation should be same to maintain.

Is This Answer Correct ?    4 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

The size and construction of bushings in a transformer depend upon?

1831


Pl.brief me any electrical major fault you have rectified.

2008


What is load boxes ?

2219


What is T’Q and X’Q and X’D ? and what is saturated as well as unsaturated ?

1833


how to select diiferent power transformers of same capacity on no load loss and full load loss by economical point of view.?

2016


operation of diesel generator

2081


i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.

1985


What is the basic principle of operation of alternators/dc generators?

1146


how to synchronize 3 phase slip ring induction motors of different ratings.

2351


What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.

8401


How to reduce -234126219.6403 MVAr generation and by what?

1685


block diagram of 2 ups system connected in parallel mode?

2122


how wecalculate breaking capcity of acb mcb mccb .explain with example

1989


if we have 320KVA Genset kindly advice how much load we can put it.

1576


How good are you in resolving the commercial issues to Employer's advantage?

2414