Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Difference between online and offline UPS?

Answer Posted / pawan pratap

IN ONLINE UPS THERE IS A DOUBLE CONVERSION AC TO DC THEN DC
TO AC.SO THERE IS NO INTERRUPTION IN ONLINE UPS WHEN MAIN
SUPPLY FAILS.BUT IN OFF LINE UPS THERE IS ONLY ONE
CONVERSION AT A TIME EITHER AC TO DC OR DC TO AC WHICH
SWITCH OVER WHEN CAHNGE OVER DONE.

Is This Answer Correct ?    29 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to test and calculat the head and discharge in borewell compressor

2114


Explain the operation principle, advantages and disadvantages of the following converters: a) A 12 pulse converter b) A Switch-mode inverter c) A thyristor inverter

1965


I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?

2157


Why frequency changes due to load variation in power system ? i.e why when load increases frequency decreases?

1867


What is the use of lag compensator?

1167


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


send me all basic electrical question and answers

2861


In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.

2055


A motor running with lenze frequiency inverter stops if I REDUCE SPEED with 25% load.If I run it in High speed and medium speed running smoothly with full load.please help me to solve it.

1929


What is s-domain and its significance?

1113


What is shunt voltage and u v voltage witch one best

1667


why ahould you show client/engineer activities clearly on the project plan

2729


what is the function of Moulded case circuit breaker, why it is called Moulded?

1501


I need bhel previous year quetion papers for electrical engineering department.I searched but i could not find out

2032


WHY THE RATINGS OF THE TRANSFORMER IS 33KV WHY NOT OTHER???

2321