Why DC excitation is used for alternators? Why cant it be AC?
Answer Posted / ashish
as we know that alternator work on the fraday's law ie when
a conductor cut the magnetic flux then a emf is induced. If
we give a.c supply than flux will also alternate and we will
get proper cuts of flux. hence we use dc supply.
| Is This Answer Correct ? | 3 Yes | 11 No |
Post New Answer View All Answers
What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load
Why mostly the HV side of transformer has Delta?
Give accurate definitions for these electric terms: Inductor Inductance Inductive Induction Reactance Reactive Esam Baraka ٢١ ساعة
wHAT IS CAPACITANCE LATCHING? hOW TO CALCULATE CAPACITANCE LATCHING? hOW TO SOLVE THE PROBLEM IF CAPACITANCE LATCHING APPLIED?
why we permissive overreach in distance protection.where it is applicable to use in long r short lines
what happen ehen synchronisation is done at below rated speed
Can we use shunt trip coil instead of trip coil with protection relay for protection?
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
explain types of electric welding and its applications
what is meant by twilight switches 7 where its applicable ?
kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased
i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.
3 phase induction motor connection star or delta while using ac drive motor is .75 to 5.5 kw
what is the id1 & id2 setting in differential protection relay of CSPC?
Cb closed condition if there is a tcs fail whether cb will trip or not