Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why earth hole size is biggest in plug point?

Answer Posted / rd dadhich

Reasons of earth Pin longer than other pins in a plug
socket :-
1. While inserting equipment first gets earth
connection.as pin goes first
2.While withdrawing the earth connection disconnects in
last
Reason of earth Pin larger in diameter than other pins in a
plug socket :-
Accidently also one can not inser earth pin in other
pins .
Both the above features are for foolfroop safety & no other
reason like low restance etc

Is This Answer Correct ?    10 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is meant by RVT and NDR ? expansion and details of it

3110


how to control dc motor?

1959


Why generation voltage in thermal power plant is between 11kv to 33kv?

1080


How does an induction motor start?

1280


1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.

2114


What is the principal of motor?

1157


how do we calculate length of starting time and repeated starting of a direct online starter?

2031


Whether the vacuum contactor requires Short circuit protection?If No,why?

2094


SIR, GIVE ME OPGW SAG CALCULATION FORMULA I AM DAE ELECTRICAL. THANKS

6954


checking procedure of capacitor based motors.used in fans etc?

2180


how we sesign the transformer give some specifion regarding design of transformers

1981


how to calculate earth fault relay current and CBCT ratio

8405


Explain the different methods used in the choice of rotor slots for reduction of harmonic torques in an induction motor.

2080


We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks

2107


What is the difference between alternator and generator?

1363