Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

depending on what we can choose the rate of mccb
considering that we know the total load

Answer Posted / jaswinder

The rating of MCCB depends on FLC for small motors but for
larger motors where factors like Load factor , diversity
factor are taken into consideration for cal of FLC and
accordingly rating of MCCB is Selected.

Is This Answer Correct ?    1 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

HOW WORK HEAT PLATE EXCHANGER

2049


What is Fire Panel ? How it works ?

2120


what is KA rating and how can we choose switchgears on applications

1503


We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks

2105


how to calculate mf when meter and cTPT detail are given

1895


Z transform is use when system is not a) converges b) diverges

1731


How to decide CT & PT ratings for a given transmission line carrying some rated voltage?

2372


How relay works, reverse relay, master relay, os relay, earth fault relay and what is its setting point

1866


how many joints are allowed in underground HT cable of 1 KM

1923


How can I known multiplying factor .without multiplying table

1879


Where can I get CPWD electrical specifications & Shedule of rates? Please help me

2300


What is trip and closing coil in cb? Why need of them

1593


What are the two segments of nyquist contour.

1163


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2772


i am completed in B.E(Electrical and Electronics Engineering) with 8 months experience in Quality Control Engineer at Bharathi Industries,Coimbatore.

1953