If induction motor load is incresed motor speed
decrases.But in syncronous motor load incrases speed
canstant why?
Answer Posted / glenn20sal
IN INDUCTION MOTOR LOAD HAS EFFECT ON SPEED
HENCE IF LOAD INCREASES SPEED DECREASE
BUT IN SYNCRONOUS MOTOR THE ROTOR NS=NR
THUS IF LOAD INCREASE ROTOR FALL BACK BY CERTAIN ANGLE
W.R.T STATOR FIELD
IF LOAD IS STILL INCREASED THERE WILL BE A POINT WHERE THE
MAGNETIC LOCK BETWEEN STATOR AND ROTOR WILL BE BROKEN AND
THE ROTOR WILL BE OUT OF SYCRONISM AND ULTIMATELY STOP
| Is This Answer Correct ? | 25 Yes | 2 No |
Post New Answer View All Answers
How Load Factor, Demand Factor, Diversity Factor etc best applied in designing an electrical circuit? Is it allowed to consider these factors in each and every panel in an electrical distribution system? Can any body suggest a good book for reference?
how to size H.T & L.T Panel ?
what is a pulse transformer? how rise time of pulse changes when ever the voltage changes?
whate is the meaning of balance/unbalance,in stabilizers type
Main advantage of auto transformer over two windings transformer is that A it needs no cooling B it uses only one winding C core losses are reduced D it has simple construction
What is the equivalent circuit of a transformer and its vector diagram?
How can you sized or estimate the ligthning arrester current rating?
What is the voltage gain or transfer function of amplifier?
what happend to DC shunt motor if its field winding insulation becomes slightly weak? will that motor can run on full load or not explain in detail. thanks
what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?
What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA
Why you are switching off arc protection mcb when you are taking shutdown for lv board.
1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.
what are the advantages and disadvantages of oil filled cables over XLPE cables
Why an ac systems are preferred over dc systems?