Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why 3 phase motors are preferable over single phase motors ?

Answer Posted / aniruddh

In case single phase motor torque devloped is zero duto
field revolving theory so we need to auxillary wdg or
paralle capacitor to improve starting torque.
In case 3- phase motor has mmf which 120degree to each
nothing required for startig purpose.
3-phase motor connected in star conection fault occurse
in any phase motor is capable to run but lower speed.

Is This Answer Correct ?    7 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Where can I get CPWD electrical specifications & Shedule of rates? Please help me

2299


In the magnetic fluxes, what is the role of armature reaction?

1204


If mutual flux is 1.2wb & power factor is 0.8 lag , then what is the Useful flux of a transformer?

4542


Haw to check conductivity of budbar

1854


We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's

1973


What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?

1652


list the type of vfd? wich is sutable for heating kiln?

2144


please tell me, how i clear the objective test? when i studied form the one book after i solved the objective ,that time i solved that qes. but if i tried solve objective form the other book then i could not solved these que.

1717


Why is water motor not taking the pressure? what is the problem?

1626


transformer spections :: input voltage 0-110-230v; output volage 0-10-12-14v; amp=3A using CRNO CORE, capcaity=50VA primary turns = ? ; secondry turns =?

2145


following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?

2115


How can we find out LT UG cable fault (size,from-4*25mm sqr to 4*300mm sqr)? How mani types UG cable faults?

3101


Define the overload capacity of the motor?

2117


How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter

7851


What is the distance between each insulator in 33kv transformer and how can it calculate

2229