DCS(distributed control system):
*Group of PLC connected in a single loop, additionaly it
cabable handle more input and output.
*A server and/or applications processor may be included
in the system for extra computational, data collection, and
reporting capability.
| Is This Answer Correct ? | 74 Yes | 12 No |
Post New Answer View All Answers
What is Positive Calibration and Negative Calibration?
how to turbine speed measurement?
the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)
how to measure draft pressure in transmitter pl. give its single line digram
How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?
what is the difference between Cv and air consumption? why the customer needs Air consumption details?
I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
Can anybody tell me which type of question are asked in the interview for the FORMULATION(Pharma) as a instrumentation engineer, & question in building managment system.
model question paper of instrumentation for Jindal GET 2010.plz reply sudhanshukumar08@yahoo.com
Where are oxygen analysers installed in cfbc boilers? What are their usual readings?
I want to apply for the universities in US,but i got the GRE score of (650+300=950)TOEFL 69/120.Is this score sufficient for applying universities please i am married i need to go to US because my husband didn't get H1 yet.please send me suggestion
What is the differerence between hysterisis and linearity.
How d.p. Transmitter can be applied to close tank?
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?