IN HT MOTOR HT REFERS TO HIGH TENSION OR HIGH TRANSMISSION?
Answer Posted / pradeep
ofcourse high tension .. we have LT motors too that is low
tension ..
| Is This Answer Correct ? | 17 Yes | 2 No |
Post New Answer View All Answers
we are having 15kw and 3kw motor both can run in same time , instead of using copper we are using ug aluminium cable , 35 sq.mm is suitable for its current carrying capacity..?
33kv substation lay out details & line to line & line to earth measurements
There are a trformer and an induction machine. Those two have the same supply. For which device the load current will be maximum? And why?
CAN ANYBODY PLEASE TELL ME HOW TO DESIGN A SERIES REACTOR FOR LIMITING SHORT CIRCUIT FAULT CURRENT??
what is the range of maximum DOL and SDS can be use for pump and fan application
Differnce between negative Pahse SequenceFunction and unbalance Function?
Difference between earthing & grounding.?
Why do we need a separate control desk & PLC control panel in Boiler plant or coal handling plant? Can we provide cost effective Control desk cum PLC panel. Is there is an specific need for control desk.. kindly advice.
Why water bubbles when D.C. Current is passed through it? Why not when A.C. Current is passed?
1. What is the exact formula for one weber? for example,(one ampere = one coulomb electron of electrons crossing a point of conductor at one second. i.e, 1A=1Q/1sec)
can i use 2000/5A Clamp meter to measure HT cable
Why do we need interlocking in a HT metering or Ring main unit switchgear?
A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
HOW WORK HEAT PLATE EXCHANGER