a 3 phase motor was running with delta connected, suddenly
one phase winding got burnt off, what will be the effect ?

Answer Posted / rvg

delta connected winding, one winding burnt off means, its
open circuited. So the motor will work as open delta system
and run normaly with non uniform torque.
The max. load that can carry will be reduced to 57.7% of
full load.
If the motor is connected through a phase faliure relay,
the relay will trip the total ckt.

Is This Answer Correct ?    111 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to design coil turns ?

1531


DEAR SIR,I GOT THE CALL LETTER FROM RRB, SECUNDERABD AS A JE-II SO PLEASE PROVIDE ME SOME MODEL QUESTION AND ANSWER PAPERS AND LAST YEAR QUESTION PAPERS

1608


How line capacitance & line inductance varies with increase in height tower.

1857


Define branch?

627


why dc is used in control circuit for mv & hv switchgear instead of ac

1450






I have motor 1500 HP and , 4160 V , 60 HZ , then i need the rating of transformer which can feed that motor ??

1397


what is advertised hop count

1269


new 90kw motor installed so how I purchased cable ,fuse,etc please give me technic for cable selected why always capacitor delta connection

1354


What would be the size of wire used for 2 Ton of window A.C?

1421


why steady state stability limit is greater than transient stability limit ? How it can be explained ?

2422


RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?

1527


how we can calculate chiller required ampear?

1590


How to calculate LT XLPE CABLE for 11 kv / 433 v , 1000 kva oil type transformer system?

1339


What should be the height of basement according to NBCC code?

1712


Describe the colour rendering properties of i) tungsten filament lamps ii) tubular fluorescent lamp

2613