How to increase the specific gravity of DG batteries?
Answer Posted / rvg.msceb
for the clear understanding, the DG batteries are always
lead acid. The specific gravities can be increased by
charging with a dc source. If the specific gravity is not
getting enough, change the electrolite,ie: sulphuric acid
and do the task again.
| Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
Why is the air gap between the pole pieces and the armature kept very small?
a governer in an Ic engine controls the
how to estimate wiring ins roughing ins. and boxes
My load is 1635 KW. & current pf is 0.884, I have to improve it for 0.99.Please suggest what KVAR value is needed?
what is the minimum pay scale for electrical engineer (building construction)in kuwait? plz revert back with yrs of experience & pay scale respectively.
why we use condenser in the thermal power plant, althrough the same vapour will be again heated
one electromagnet is called
I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?
What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
Y phase plates are used in transmission line??? what is there need???
How to know of any cable size if there are not written on cabl?
how many types are their in switchyard or substation(like D,I TYPE), what is differant between them
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
What is installed in PAC that is control the humidity