What is the difference between short circuit and overload
currents?
Answer Posted / asutosh
short circuit current is of the order of 100 times that of
normal rating & it is expessed in kA.
the increase in normal rating due to anything rather than
short circuit is kwon as over load current
| Is This Answer Correct ? | 82 Yes | 42 No |
Post New Answer View All Answers
why we can use 1 to 5V dc
show the single line diagram of star delta starter with single phase preventer
how does the thyistor work in dc drive?
what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv
Use of switch mode power converter in real-time basis?
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
Explain and give me an example of a time when you had to explain some new procedures to your co-workers for quality service delivery, how did you go about it?
brief notes on ammeters
why sielent pole is used only in hydro generators and not in turbo generators
how to determine Sq.mm size of finolex power cables.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what is the difference between b c d curves on mcb
is it possible to say motor horsepower number without seeing name plate(when name plate damaged)
132/6.6ππ πππππππππππ πππππππ πππ πππ πππππ πππ πππππππππ. πΈ'ππ πππππππ πππππππππππ ππ 6.6ππ/415π πππ πΈ πππππππ πππππππ ππ ππππ πππππ πππ ππ ππ 13/6.ππ πππππππππππ?? πΈπ π½π.. ππππ π ππ’??
What is the RME and explain the full form and what is the RME work?