Can any body help me,The GE Mark V control system is
windows based or Dos based?
Answer Posted / prasannashankar
GE mark v control system is dos based system.
| Is This Answer Correct ? | 16 Yes | 3 No |
Post New Answer View All Answers
what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.
What is sensitivity in vibration probes..?
What is difference between “Fault Tolerant” & “Fault avoidance” PLC? Application where these system s are used?
hello sir/madam, I,Subramanian need 5yrs placement papers of officer trainee of Instrumentation technology.pls send to this mail id mani_nxtgen@yahoo.co.in please do the needful. with regards, subramanian.v
What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
What is offset in a control system.
Can I calibrate the Electromagnetic Flow Meter on line and How.
There are two chlorination tonners both are connected to two pressure swithes and the pressure switch is connected to SOV which operates the valve to changeover the tonner selection i.e if pressure one tonner goes low the other tonner should come in line if it is inautomatic selection design a circuit using relays ?
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
what can of fault ofently come in vibration mesurement?
why is not useing in boiler skin thermocople
How INtools is useful for routine Instrument maintenance?
can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.
give some question relative instrument fitter?